FITNESS FOR SERVICE ANALYSIS
Industry
Petro Chemical
Service
Petro Chemical
Expertise
Petro Chemical
Background
• Separator nozzle N1 was suffering from crevice corrosion due to moisture ingress via the weep hole in the reinforcement pad.
• Preliminary code calculations were not fully conclusive as to the fitness for service of this item and therefore a Level 3 assessment using a linear elastic Finite Element Analysis (FEA) model was built.
Outcomes
- The maximum stress utilisation was evaluated to be 91.8% and is based on the
current estimated remaining wall thickness (RWT) of 9.6mm with no future corrosion
allowance (FCA) included. - The nozzle was verified against the loads provided by operator and found to be fit for
service in the current state. - The fracture mechanics assessment revealed on the FAD that the equipment was
safe.
Challenges
• Bespoke geometry of the cut-out in the nozzle pad had to be modelled.
• Low cycle fatigue evaluation required using fracture mechanics approach